00015
Carrier Transicold
Critical
Battery Voltage Too High
The system detects a battery voltage exceeding 15.5V DC.
Possible causes
- Defective alternator regulator
- Corroded voltage sensor cables
- Damaged internal microprocessor battery
- Inappropriate external charger use
Recommended actions
- Measure voltage with external multimeter
- Replace alternator regulator
- Clean battery terminals
- Reset APX controller
Can't find your code? Talk to an expert
$150
One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.