00058
Carrier Transicold
Warning

Check Remote Switch 2

Failure in the remote switch 2 circuit, typically tied to a door sensor or auxiliary input. Close all compartment doors; if the unit remains shut down, repair immediately.

Possible causes

  • Door or auxiliary switch open or stuck
  • Damaged remote switch 2 wiring
  • Faulty magnet or sensor on the second door
  • Loose terminal at the APX controller

Recommended actions

  • Close all compartment doors firmly
  • Inspect remote switch 2 wiring continuity
  • Test the switch with a jumper to isolate hardware fault
  • Replace magnet or sensor if alignment is lost