00058
Carrier Transicold
Warning
Check Remote Switch 2
Failure in the remote switch 2 circuit, typically tied to a door sensor or auxiliary input. Close all compartment doors; if the unit remains shut down, repair immediately.
Possible causes
- Door or auxiliary switch open or stuck
- Damaged remote switch 2 wiring
- Faulty magnet or sensor on the second door
- Loose terminal at the APX controller
Recommended actions
- Close all compartment doors firmly
- Inspect remote switch 2 wiring continuity
- Test the switch with a jumper to isolate hardware fault
- Replace magnet or sensor if alignment is lost