00061
Carrier Transicold
Warning
Door Open
The sensor indicates a compartment door is open, stopping the unit.
Possible causes
- Improperly closed door
- Faulty magnetic door switch
- Missing or broken door magnet
- Short circuit in door wiring harness
Recommended actions
- Close all doors firmly
- Check for presence of magnets on door leaves
- Verify magnetic sensor condition
- Inspect connector condition at the top of the frame