00062
Carrier Transicold
Warning

C2 Box Temp Out of Range

Second compartment (C2) temperature is outside allowable limits.

Possible causes

  • Incorrect cargo stowage in C2
  • Air leakage between bulkheads
  • C2 remote evaporator blocked by ice
  • Stuck liquid solenoid valve

Recommended actions

  • Inspect bulkhead sealing
  • Perform manual defrost on C2 remote unit
  • Verify multi-temperature setpoint settings
  • Check C2 fan operation