00085
Carrier Transicold
Warning

Check UL1 Circuit

Electrical failure detected in the Compressor Unloader 1 (UL1) circuit.

Possible causes

  • Defective UL1 solenoid coil
  • Damaged control relay
  • Exposed or broken wires
  • Microprocessor port failure

Recommended actions

  • Measure UL1 coil resistance
  • Check solenoid with test magnet
  • Inspect harness near compressor
  • Verify operation in diagnostic mode