00096
Carrier Transicold
Critical
Check GENCONR Relay Coil
Failure in the GENCONR relay coil (Generator Contactor).
Possible causes
- Open power contactor coil
- Generator exciter problem
- Loose high-vibration connections
Recommended actions
- Verify generator output
- Tighten terminals on the GENCONR contactor
- Replace relay if coil has no continuity
Can't find your code? Talk to an expert
$150
One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.
Other Carrier Transicold codes
Need a professional diagnosis?
Low Temp Service — refrigeration experts in Florida.