00102
Carrier Transicold
Critical

C3 Evap Motor Overheated

Overheating detected in the Compartment 3 evaporator motor.

Possible causes

  • Physical obstruction of the fan blades
  • Phase failure in the motor
  • Excessive use under extreme conditions

Recommended actions

  • Manual blade rotation to rule out blockage
  • Verify connections in the motor terminal box
  • Measure motor winding resistance