00110
Carrier Transicold
Critical
Check 2EVCON Relay Coil
Fault in the evaporator motor contactor 2 (2EVCON).
Possible causes
- Defective relay or contactor
- Damaged evaporator 2 wire harness
- Missing signal from controller
Recommended actions
- Swap relay to validate operation
- Check power wires to Evaporator 2
- Confirm evaporator motor 2 is not seized
Can't find your code? Talk to an expert
$150
One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.
Other Carrier Transicold codes
Need a professional diagnosis?
Low Temp Service — refrigeration experts in Florida.