00123
Carrier Transicold
Warning

Check Supply Air Sensor

Fault detected on the supply air temperature sensor (SAS). If the unit shut down, repair immediately; otherwise report and repair at end of trip.

Possible causes

  • Defective supply air sensor
  • Open or shorted sensor wiring
  • Corroded sensor connector
  • Sensor displaced from air discharge stream

Recommended actions

  • Measure SAS resistance against the temperature table
  • Inspect and clean sensor connector
  • Verify wiring continuity to the controller
  • Replace sensor if reading is out of range