00123
Carrier Transicold
Warning
Check Supply Air Sensor
Fault detected on the supply air temperature sensor (SAS). If the unit shut down, repair immediately; otherwise report and repair at end of trip.
Possible causes
- Defective supply air sensor
- Open or shorted sensor wiring
- Corroded sensor connector
- Sensor displaced from air discharge stream
Recommended actions
- Measure SAS resistance against the temperature table
- Inspect and clean sensor connector
- Verify wiring continuity to the controller
- Replace sensor if reading is out of range