00136
Carrier Transicold
Warning

C2 Check Supply Air Sensor

Supply air sensor error for compartment 2 (C2).

Possible causes

  • Defective SAS2 sensor
  • Restricted airflow
  • C2 evaporator harness disconnection

Recommended actions

  • Measure SAS2 sensor resistance
  • Verify supply air is not obstructed
  • Inspect distribution board connections

Can't find your code? Talk to an expert

$150

One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.

Have a question? Ask the community

Thousands of refrigeration mechanics read and answer for free. Post your case in under 1 minute.

Need a professional diagnosis?

Low Temp Service — refrigeration experts in Florida.

Contact us