00243
Carrier Transicold
Warning

Suct/Evap Calibrate Error

Calibration error in the suction or evaporator pressure sensors.

Possible causes

  • Defective or out-of-calibration suction transducer
  • Damaged or moisture-compromised signal wires
  • Processing error on the analog board

Recommended actions

  • Compare sensor readings against gauges
  • Clean transducer connectors
  • Attempt recalibration via the service menu
  • Replace the suction/evaporator sensor