00248
Carrier Transicold
Critical

Config Mode / HP2 Error

Conflict between the selected configuration mode and the high pressure sensor (HP2).

Possible causes

  • Incorrect hardware configuration
  • HP2 sensor incorrectly connected or wrong type
  • Failure in high pressure protection detection

Recommended actions

  • Validate configuration matches the physical model
  • Inspect HP2 high pressure switch connection
  • Check Jumpers or configuration parameters
  • Replace HP2 sensor if shorted