25100
Carrier Transicold
Critical

No Comm From Micro to STP1

Communication failure between the microprocessor and the stepper motor module 1 (STP1).

Possible causes

  • Loose data bus connector
  • Power failure to STP1
  • Electromagnetic interference
  • Hardware failure on the STP1 board

Recommended actions

  • Inspect and tighten communication connectors
  • Verify power supply to STP1 board
  • Check CAN bus termination resistors
  • Replace STP1 board if persists after reset