25200
Carrier Transicold
Critical

No Comm From Micro to STP2

Communication failure between the microprocessor and the stepper motor module 2 (STP2).

Possible causes

  • Interrupted communication harness
  • Lack of voltage to STP2
  • Incorrect module addressing
  • Defective STP2 board

Recommended actions

  • Verify CAN wiring continuity
  • Measure 12V/24V supply at STP2 connector
  • Inspect main microprocessor pins
  • Replace STP2 module

Can't find your code? Talk to an expert