25200
Carrier Transicold
Critical
No Comm From Micro to STP2
Communication failure between the microprocessor and the stepper motor module 2 (STP2).
Possible causes
- Interrupted communication harness
- Lack of voltage to STP2
- Incorrect module addressing
- Defective STP2 board
Recommended actions
- Verify CAN wiring continuity
- Measure 12V/24V supply at STP2 connector
- Inspect main microprocessor pins
- Replace STP2 module