26109
Carrier Transicold
Critical

Actuator Abnormal ENCU

Anomaly detected in the electrical operation of the engine actuator.

Possible causes

  • Burnt stop or throttle solenoid
  • Defective actuator relay
  • Open wiring to the actuator
  • ENCU power output failure

Recommended actions

  • Measure actuator solenoid resistance
  • Verify actuator power wires
  • Test injection relay
  • Repair loose connectors

Can't find your code? Talk to an expert

$150

One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.

Have a question? Ask the community

Thousands of refrigeration mechanics read and answer for free. Post your case in under 1 minute.