26200
Carrier Transicold
Critical
EES Loss of Communication to Controller
The emissions after-treatment system (EES) lost CAN/serial communication with the main controller.
Possible causes
- Damaged or disconnected CAN harness between EES and controller
- EES ECU not powered (blown fuse)
- Failed EES ECU
- Termination resistor or CAN bus fault
Recommended actions
- Inspect EES harness and connectors
- Verify EES ECU power and ground
- Check CAN bus voltages and termination
- Reset; if alarm reactivates, replace EES ECU
Can't find your code? Talk to an expert