P00160
Carrier Transicold
Critical

Check Disch Temp Sensor

Compressor discharge temperature sensor out of range.

Possible causes

  • Damaged thermal sensor
  • Compressor operating with high pressure/heat
  • Lack of refrigerant

Recommended actions

  • Inspect discharge sensor on cylinder head
  • Check high and low system pressures
  • Verify condenser airflow