P00164
Carrier Transicold
Warning

Check UL2 Circuit

Fault in the cylinder loader/unloader number 2 (UL2) circuit.

Possible causes

  • Unloader valve coil burned out
  • Valve stem stuck
  • Controller driver failure

Recommended actions

  • Check UL2 coil resistance
  • Perform software-forced actuation test
  • Replace coil or valve if necessary