P00197
Carrier Transicold
Critical

Check Clutch

Failure in the coupling or electromagnetic clutch of the compressor.

Possible causes

  • Burnt clutch coil
  • Incorrect plate clearance
  • Loss of voltage to the clutch

Recommended actions

  • Measure clutch air gap
  • Verify power supply to the clutch cable
  • Check condition of the drive belt