P00213
Carrier Transicold
Warning
Check Damper CR2 Circuit
Failure detected in the damper relay circuit CR2.
Possible causes
- Burnt damper coil
- Stuck mechanism
- CR2 signal failure
Recommended actions
- Grease and free damper mechanism
- Check for 12V at the actuator
- Check relay in control box