P13000
Carrier Transicold
Critical

Check Condenser Fan 2 Circuit

Failure in the condenser fan number 2 circuit during self-check.

Possible causes

  • Burned out fan motor
  • Blown fuse or relay
  • Mechanical blockage of the blades

Recommended actions

  • Check for obstructions in the fan blades
  • Check motor fuses and contactors
  • Measure voltage at fan motor 2
  • Replace the fan motor if an open circuit exists