P14003
Carrier Transicold
Warning

C3 Chk Evap2 Superheat

Superheat out of range in evaporator 2 of compartment 3.

Possible causes

  • Error in superheat control logic
  • Defective C3 suction sensor
  • EEV valve mechanical failure

Recommended actions

  • Check connections for EEV number 2 in C3
  • Verify pipe temperature sensors
  • Restart system and run Pre-Trip
  • Replace valve or sensor according to result

Can't find your code? Talk to an expert

$150

One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.

Have a question? Ask the community

Thousands of refrigeration mechanics read and answer for free. Post your case in under 1 minute.

Need a professional diagnosis?