101
Thermo King
Info

Controlling on Evap Coil Outlet Temp (CR)

Unit is controlling temperature based on evaporator outlet due to a primary sensor failure.

Possible causes

  • Return air sensor failure
  • Erratic discharge air sensor reading
  • Controller configuration error
  • Sensor communication issues

Recommended actions

  • Check for additional temperature sensor alarms
  • Manually monitor cargo temperature
  • Calibrate or replace return air sensor
  • Review microprocessor control parameters