104
Thermo King
Warning

Check Remote Fan Speed (Zone)

The controller cannot detect or maintain the required speed for the remote zone fans.

Possible causes

  • Loose or broken fan belts
  • Remote fan motor with worn brushes or electrical failure
  • Speed sensor (tachometer) failure
  • Voltage drop to remote evaporators

Recommended actions

  • Physically inspect remote fans
  • Check motor condition and connections
  • Verify voltage at motor terminals
  • Clear codes and test in high speed mode