110
Thermo King
Critical

Check Suction Line Sol Circuit (Zone)

Failure in the suction line solenoid valve circuit for a specific zone.

Possible causes

  • Burnt zone suction coil
  • Wiring failure between controller and zone
  • Defective zone relay
  • Corroded connection at remote evaporator

Recommended actions

  • Verify power supply to suction solenoid
  • Measure valve coil resistance
  • Check for short circuit signs in zone harness
  • Replace solenoid if no magnetism when energized