111
Thermo King
Warning

Unit Not Configured Correctly (Zone)

The unit configuration does not match the hardware or number of zones installed.

Possible causes

  • Incorrect software configuration after board replacement
  • Microprocessor memory loss
  • Detected sensors mismatch programmed mode
  • Multi-temperature configuration error

Recommended actions

  • Enter technical configuration menu
  • Verify model and zone count are correct
  • Perform full factory reset if necessary
  • Confirm correct jumper settings on board

Can't find your code? Talk to an expert