121
Thermo King
Critical
Check PMW Liquid Injection Circuit
Failure in the Pulse Width Modulation (PMW) liquid injection circuit, crucial for compressor cooling.
Possible causes
- Defective injection solenoid coil
- Obstruction in the injection line
- Failure in the discharge temperature sensor
- Problem with the controller output driver
Recommended actions
- Test PMW solenoid resistance
- Verify solenoid opens when discharge temperature rises
- Check discharge sensor (Code 86)
- Clean liquid line filters
Can't find your code? Talk to an expert
$150
One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.
Other Thermo King codes