141
Thermo King
Warning

Auto Switch Diesel to Electric Disabled

The unit was unable to perform the automatic switch from Diesel to Electric power.

Possible causes

  • Insufficient or absent grid voltage
  • Selector switch in manual position
  • Phase presence sensor failure

Recommended actions

  • Validate power cord is properly connected
  • Measure voltage at the power outlet
  • Verify electric priority mode configuration