144
Thermo King
Warning

Lost CAN Communications to Expansion Module

Loss of communication between the main controller and the expansion module.

Possible causes

  • CAN bus wires (H and L) damaged or cut
  • Power failure to the expansion module
  • Excessive electromagnetic interference

Recommended actions

  • Verify integrity of the CAN wire harness
  • Measure supply voltages to the expansion module
  • Check for 60 ohm termination resistance on the CAN bus