156
Thermo King
Warning

Check Suction/Liquid Heat Exchanger Bypass Valve

Indicates a problem with the operation of the suction/liquid heat exchanger bypass valve.

Possible causes

  • Defective solenoid valve
  • Loose or corroded electrical connection
  • Blockage in the refrigerant line

Recommended actions

  • Perform valve diagnostic test on the controller
  • Measure valve coil resistance
  • Verify wire harness continuity to the controller