47
Thermo King
Critical

Remote Sensor Shutdown

Critical failure in a remote temperature sensor that prevents safe operation.

Possible causes

  • Remote temperature sensor disconnected
  • Cut or damaged sensor cable
  • Sensor out of calibration (short circuit)
  • Loose connection point in control box

Recommended actions

  • Verify physical connection of remote sensor
  • Measure sensor resistance (Ohms) vs temperature
  • Inspect wiring integrity along the path
  • Replace sensor to rule out internal failure