514
Thermo King
Warning
Low Compressor Discharge Pressure (Scroll Only)
Scroll compressor discharge pressure too low during operation.
Possible causes
- Low refrigerant charge in the system
- Worn or internally damaged scroll compressor
- Failed discharge check valves
- Extremely low ambient temperature
Recommended actions
- Apply refrigerant charge as needed
- Perform compressor efficiency test
- Inspect bypass and check valves
- Confirm condenser fans are not over-spinning