516
Thermo King
Critical
I/O Controller to Application Controller Com Failure
Critical communication failure between I/O controller and application controller.
Possible causes
- Poor contact in ribbon cables or data jumpers
- Power failure on one of the electronic boards
- Severe electrical interference
- Defective application controller
Recommended actions
- Power down unit and reseat all board connectors
- Measure supply voltages on both controllers
- Verify ground wires and communication shielding
- Replace controller if error persists after reboot