524
Thermo King
Warning

Generator Op Limit Vout to Frequency Ratio

Generator Voltage/Frequency ratio is outside functional limits.

Possible causes

  • Defective voltage regulator (AVR)
  • Unstable engine speed
  • Electrical overload on generator
  • Incorrect parameter configuration in controller

Recommended actions

  • Adjust engine governor to stabilize RPM
  • Check or replace generator AVR
  • Verify electrical loads do not exceed capacity
  • Measure frequency and voltage with external multimeter