544
Thermo King
Warning

Battery Charger External Short

A short circuit has been detected in the wiring or load external to the battery charger.

Possible causes

  • Output cable rubbing against unit chassis
  • Battery with shorted internal plate
  • Defective 12V auxiliary accessories
  • Damaged charger output connector

Recommended actions

  • Inspect charger output wiring harness
  • Test battery with a conductance analyzer
  • Disconnect external loads to locate the short
  • Check battery terminals and insulators