56
Thermo King
Warning

Check Evaporator Fan Low Speed (Zone)

Failure detected in the evaporator fans' low-speed circuit.

Possible causes

  • Defective low-speed relay
  • Damaged fan motor
  • Open wiring or high resistance
  • Blown fan fuse

Recommended actions

  • Test fan motors individually
  • Verify speed control relays
  • Inspect terminal box connections
  • Measure motor amperage

Can't find your code? Talk to an expert

$150

One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.

Have a question? Ask the community

Thousands of refrigeration mechanics read and answer for free. Post your case in under 1 minute.

Need a professional diagnosis?

Low Temp Service — refrigeration experts in Florida.

Contact us