82
Thermo King
Critical

High Compressor Temp Shutdown

The unit stopped to protect the compressor due to excessive temperature.

Possible causes

  • Critical lack of refrigerant
  • Total lubrication failure
  • Damaged discharge valve
  • Refrigeration system blockage

Recommended actions

  • Allow compressor to cool before restarting
  • Check refrigerant charge
  • Verify fan operation
  • Check solenoid valves and ETV

Can't find your code? Talk to an expert

$150

One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.

Have a question? Ask the community

Thousands of refrigeration mechanics read and answer for free. Post your case in under 1 minute.

Need a professional diagnosis?

Low Temp Service — refrigeration experts in Florida.

Contact us