HP
Thermo King
Critical

High Discharge Pressure (DSR)

Discharge pressure exceeded safe operating limit and shut down the unit.

Possible causes

  • Dirty or blocked condenser coil
  • Failed condenser fan
  • Overcharge of refrigerant
  • Non-condensables in the system

Recommended actions

  • Clean condenser coil
  • Verify condenser fan operation
  • Check refrigerant charge
  • Recover and recharge if contaminated