Defrost Problems / Ice Buildup

70 related codes

Defrost cycle not initiating, terminating early, or evaporator iced over. Often a defrost termination switch, heater or timer fault.

AL10
Carrier Transicold

Alarm 10 – Supply Air Temperature Sensor (SATS) Out of Range

Carrier Transicold alarm AL10 (Alarm Code 10) means the Advance microprocessor has detected the Supply Air Temperature Sensor (SATS/STS) reading is out of range, open, or shorted. The SATS lives in the discharge airstream after the evaporator on Vector, X4, X2 and Supra reefer units and is the primary control sensor when 'Supply' is selected. When AL10 latches, the controller falls back to the Return Air Sensor and box temperature control becomes unstable — a frequent cause of load-quality claims.

00017
Carrier Transicold

Alarm 17 – High Compressor Discharge Temperature (CDT)

Carrier Transicold alarm code 17 (AL17) triggers when Compressor Discharge Temperature (CDT) climbs above the safety threshold — typically 310°F (154°C) on Vector, X4, X2 and Supra reefer units. The Advance controller shuts the unit down to protect the compressor from thermal breakdown of oil, valve plate damage, and burned windings. AL17 almost always points at a refrigerant-side or airflow problem, not the compressor itself.

00028
Carrier Transicold

Check Refrig System

The system detected poor cooling efficiency.

00054
Carrier Transicold

Defrost Not Complete

The defrost cycle has exceeded the maximum allowed time without completing correctly.

00055
Carrier Transicold

Check Defrost Air Switch

Failure detected in the air pressure switch that initiates or monitors defrost.

00056
Carrier Transicold

Check Evaporator Air Flow

The system has detected a significant restriction in airflow through the evaporator.

00062
Carrier Transicold

C2 Box Temp Out of Range

Second compartment (C2) temperature is outside allowable limits.

00077
Carrier Transicold

Evap Motor Overheated

The evaporator fan motor is operating above its safe temperature threshold.

00081
Carrier Transicold

Check FHR Circuit

Failure in the Fuel Heater Relay (FHR) or heater circuit.

00083
Carrier Transicold

Check Remote Defrost Light

Electrical issue detected in the remote Defrost indicator light circuit.

00114
Carrier Transicold

Check LIV Circuit

Fault in the liquid injection valve (LIV) circuit.

00124
Carrier Transicold

Check Defrost Termination 1 Sensor

Defrost termination sensor 1 detects an out-of-range or open circuit condition.

00128
Carrier Transicold

Low/Unbalanced A/C Amps

Low or unbalanced AC current amperage detected at the generator.

00132
Carrier Transicold

Check Defrost Termination 2 Sensor

Failure in the secondary defrost termination sensor (DTS2).

00139
Carrier Transicold

C2 Check Defrost Sensor

Defrost sensor error for compartment 2 (C2).

00140
Carrier Transicold

C3 Check Defrost Sensor

Defrost sensor error for compartment 3 (C3).

P00146
Carrier Transicold

C2 Check Heater 1 Circuit

Failure in compartment 2 (C2) heater 1 circuit.

P00147
Carrier Transicold

C2 Check Heater 2 Circuit

Failure in compartment 2 (C2) heater 2 circuit.

P00159
Carrier Transicold

Check Defrost Term 1 Sensor

Failure in defrost termination sensor number 1.

P00163
Carrier Transicold

C3 Check Heater 1 Circuit

Failure in heating circuit 1 for compartment 3.

P00167
Carrier Transicold

C3 Check Heater 2 Circuit

Failure in the compartment 3 heating circuit 2.

P00179
Carrier Transicold

Check LIV

Flow or mechanical failure in the Liquid Injection Valve (LIV).

P00187
Carrier Transicold

Check Heater 1 Circuit

A fault was detected in the Heater 1 electrical circuit during Pretrip.

P00188
Carrier Transicold

Check Heater 2 Circuit

Fault detected in the Heater 2 circuit, preventing effective defrost or heating.

P00205
Carrier Transicold

Check Defrost Term 2 Sensor

Failure in the evaporator 2 defrost termination sensor.

P00211
Carrier Transicold

C2 Check Defrost Sensor

Failure in the compartment 2 defrost sensor.

P00212
Carrier Transicold

C3 Check Defrost Sensor

Failure in the compartment 3 defrost sensor.

P00215
Carrier Transicold

Check Damper – Not Open

The defrost damper is stuck in the closed position or is not opening properly.

P00216
Carrier Transicold

Check Damper – Not Closing

The defrost damper does not close properly, preventing proper airflow during refrigeration.

00223
Carrier Transicold

Engine Maintenance Due

Indicates that the engine runtime interval for preventive maintenance has been reached.

00224
Carrier Transicold

Standby Maintenance Due

The scheduled interval for electric motor (Standby) service has expired.

00225
Carrier Transicold

General Maintenance Due

General maintenance alert suggesting a global preventive review of the equipment.

00226
Carrier Transicold

Service Soon PM 1 Due

Notification that the first level of preventive maintenance (PM 1) is required.

00227
Carrier Transicold

Service Soon PM 2 Due

Notification that the second level of preventive maintenance (PM 2) is required.

00228
Carrier Transicold

Service Soon PM 3 Due

Notification that the third level of preventive maintenance (PM 3) is required.

00229
Carrier Transicold

Service Soon PM 4 Due

Notification that the fourth level of preventive maintenance (PM 4) is required.

00230
Carrier Transicold

Service Soon PM 5 Due

Notification that the fifth level of preventive maintenance (PM 5) is required.

05020
Carrier Transicold

Check Htr Cntr One

Problem detected in electric heater contactor 1.

05021
Carrier Transicold

Check Htr Cntr Two

Problem detected in electric heater contactor 2.

07003
Carrier Transicold

C2 Chk Evap Temp Sensor

Indicates a problem with the evaporator temperature sensor in compartment 2.

26200
Carrier Transicold

EES Loss of Communication to Controller

The emissions after-treatment system (EES) lost CAN/serial communication with the main controller.

26201
Carrier Transicold

EES Service Required

The emission system (EES) requires maintenance or a functional failure has been detected.

26220
Carrier Transicold

EES Back Pressure Exceeded

Exhaust pressure has exceeded the absolute safety limit for engine operation.

27100
Carrier Transicold

No Comm from Micro to Comm Module

Loss of communication between the main microprocessor and the communication module.

04
Thermo King

Check (Control) Discharge Air Sensor (Zone)

Failure of the discharge air sensor, which measures the air leaving the evaporator toward the cargo.

14
Thermo King

Defrost Terminated by Time

The defrost cycle ended due to maximum time limit instead of temperature termination.

15
Thermo King

Check Glow Plugs or Intake Air Heater

Failure detected in the intake air heater or glow plug circuit.

26
Thermo King

Check Refrigeration Capacity (Zone)

Refrigeration capacity is lower than expected for the current setpoint.

29
Thermo King

Defrost Damper Circuit Check (Zone)

The circuit controlling the defrost damper exhibits a failure.

30
Thermo King

Defrost Damper Stuck Closed (Zone)

The evaporator damper has become stuck in the closed position.

46
Thermo King

Check Air Flow (Zone)

Restriction detected in evaporator airflow in the indicated zone.

100
Thermo King

Heater Fan Failure (CR)

Fault detected in the heater fan motor or circuit.

102
Thermo King

Low Evaporator Coil Temperature (CR)

Evaporator coil temperature is dangerously low, which may lead to icing or freezing.

103
Thermo King

Low Heater Fuel Level (CR)

Low fuel level detected specifically within the auxiliary heating system.

122
Thermo King

Check Diesel/Electric Circuit

Error when attempting to switch between diesel and electric mode or vice versa.

128
Thermo King

Engine Run Time Maint Reminder #1/Service Due

Preventive maintenance reminder based on diesel engine operating hours.

129
Thermo King

Engine Run Time Maint Reminder #2

Second preventive maintenance reminder for the diesel engine.

133
Thermo King

Total Unit Run Time Maint Reminder #2

Second maintenance notification based on the total accumulated unit run time.

137
Thermo King

Check Damper Motor Heater Output

Fault in the heater circuit for the defrost damper motor.

139
Thermo King

Abort Evacuation Mode

The evacuation (vacuum) mode has been aborted due to an error or manual intervention.

142
Thermo King

Check Thermax Valve

Fault detected in the Thermax valve of the heating/defrost system.

143
Thermo King

Check Remote Drain Hose Heater Output (Zone)

Error in the remote drain hose heater output in a specific zone.

204
Thermo King

Check Display Discharge Air Sensor (Zone)

The display discharge air temperature sensor is presenting erroneous readings.

528
Thermo King

Failed J1939 CAN Comm Base Controller/Charger

J1939 CAN communication failure between the base controller and the battery charger.

538
Thermo King

Engine J1939 CAN Data Link Degraded

The engine J1939 data network is operating but with constant errors (degraded).

E6
Danfoss

Data Communication Failure

Loss of communication with the master controller or module.

A1
Danfoss

High Temperature Alarm

Temperature above the configured limit.

00570
Thermo King

Clean EGR Soon

Engine ECU indicates the EGR (Exhaust Gas Recirculation) system requires cleaning maintenance.

00599
Thermo King

Engine Service Tool Connected

Informational alarm indicating a diagnostic service tool is connected to the engine ECU.

OL
Thermo King

Electric Standby Overload (DSR)

Electric standby motor drew excessive current and tripped the overload protection.