Electrical Faults (Voltage, Battery, Wiring)
310 related codes
Battery voltage out of range, alternator not charging, blown fuse, shorted harness, or contactor/relay failures.
Alarm 10 – Supply Air Temperature Sensor (SATS) Out of Range
Carrier Transicold alarm AL10 (Alarm Code 10) means the Advance microprocessor has detected the Supply Air Temperature Sensor (SATS/STS) reading is out of range, open, or shorted. The SATS lives in the discharge airstream after the evaporator on Vector, X4, X2 and Supra reefer units and is the primary control sensor when 'Supply' is selected. When AL10 latches, the controller falls back to the Return Air Sensor and box temperature control becomes unstable — a frequent cause of load-quality claims.
High A/C Amps
High electrical current detected in AC system components.
Battery Voltage Too High
The system detects a battery voltage exceeding 15.5V DC.
Battery Voltage Too Low
Battery voltage is below 10V DC during operation.
A/C Current Over Limit
AC current consumption exceeded pre-set limits.
Failed To Start – Auto Mode
Engine failed to start after maximum allowed automatic attempts.
Failed To Start – Manual
Failure to start the unit in manual mode.
Engine Failed to Stop
The engine does not shut down when the controller sends the signal.
Check Starter Circuit
Anomaly detected in the starter motor electrical circuit.
Check Engine RPM
The engine is not reaching or maintaining the required RPM for the operating cycle.
Check Engine Preheat Circuit
A problem has been detected in the preheat circuit (glow plugs), making cold starting difficult.
Alternator (Battery Charger) Not Charging
The alternator is not charging the unit's battery while the engine is running.
Check Remote Switch 1
Fail in the remote switch 1 circuit, usually related to door sensors or auxiliary switches.
Check Remote Switch 2
Failure in the remote switch 2 circuit, typically tied to a door sensor or auxiliary input. Close all compartment doors; if the unit remains shut down, repair immediately.
Datalogger Time Wrong
The internal data logger time and date do not match the current actual time.
Door Open
The sensor indicates a compartment door is open, stopping the unit.
Bad F2 or F3 Fuse
Failure in fuses F2 or F3 which control vital accessory power circuits.
Bad F4 or F6 Fuse
Failure detected in fuses F4 or F6, affecting control or lighting circuits.
AC Phase Reversed
External AC power phase is reversed, which can damage motors.
Compressor Motor Overload
The compressor motor overload relay has tripped due to excessive current.
Evap Motor Overheated
The evaporator fan motor is operating above its safe temperature threshold.
Check SV1 Circuit
Failure detected in the SV1 solenoid valve electrical circuit.
Check SV4 Circuit
Failure detected in the SV4 solenoid valve electrical circuit.
Check SV3 Circuit
Failure detected in the SV3 solenoid valve electrical circuit.
Check FHR Circuit
Failure in the Fuel Heater Relay (FHR) or heater circuit.
Check Remote Out of Range Light
The microprocessor detects an issue with the remote "Out of Range" indicator light.
Check Remote Defrost Light
Electrical issue detected in the remote Defrost indicator light circuit.
Check UL1 Circuit
Electrical failure detected in the Compressor Unloader 1 (UL1) circuit.
Check UL2 Circuit
Electrical failure detected in the Compressor Unloader 2 (UL2) circuit.
Check Remote Heat Light
The system reports a circuit problem with the remote heat indicator light.
Check Remote Cool Light
A problem has been detected in the remote cooling indicator light (Cool Light) circuit.
Check Remote Auto Light
Failure detected in the remote automatic mode light circuit (Auto Light).
Check AFA Solenoid Circuit
Problem in the air purifier solenoid circuit (AFA Solenoid).
Check 1HTCON1 Relay Coil
Failure in the 1HTCON1 relay coil (Heating Contactor 1).
Check 1HTCON2 Relay Coil
Failure in the 1HTCON2 relay coil (Heating Contactor 2).
Check Start Up Buzzer
Failure in the pre-start safety buzzer.
Check Comp Contactor 1
Error in compressor contactor 1.
Check CDCON Relay Coil
Failure in the CDCON relay coil (Condenser Fan).
Check GENCONR Relay Coil
Failure in the GENCONR relay coil (Generator Contactor).
Check SV2 Circuit
Issue detected in the SV2 (Hot Gas) solenoid valve circuit.
Check Standby Contactor
Failure in the electric standby mode contactor coil or circuit.
Check 2HTCON1 Relay Coil
Failure in the 2HTCON1 relay coil (Compartment 2 Heat 1).
Check 2HTCON2 Relay Coil
Failure in the 2HTCON2 relay coil (Compartment 2 Heat 2).
Check 3HTCON1 Relay Coil
Failure in the 3HTCON1 relay coil (Compartment 3 Heat 1).
Check 3HTCON2 Relay Coil
Failure in the 3HTCON2 relay coil (Compartment 3 Heat 2).
Check 2LSV Circuit
Issue in the Liquid Line Solenoid Valve 2 (2LSV) circuit.
Check 3LSV Circuit
Issue in the Liquid Line Solenoid Valve 3 (3LSV) circuit.
Check 1EVCON Relay Coil
Fault in the evaporator motor contactor 1 (1EVCON).
Check 2EVCON Relay Coil
Fault in the evaporator motor contactor 2 (2EVCON).
Check 3EVCON Relay Coil
Fault in the evaporator motor contactor 3 (3EVCON).
Check Economizer Circuit
Failure in the economizer circuit.
Check DCR2 Circuit
Fault in the DCR2 relay (Data Control Relay) circuit.
Check Return Air Sensor
Failure in the return air temperature sensor.
Check Supply Air Sensor
Fault detected on the supply air temperature sensor (SAS). If the unit shut down, repair immediately; otherwise report and repair at end of trip.
Check Defrost Termination 1 Sensor
Defrost termination sensor 1 detects an out-of-range or open circuit condition.
Check Suction Temp Sensor
Failure in the suction temperature sensor circuit.
Low/Unbalanced A/C Amps
Low or unbalanced AC current amperage detected at the generator.
Check Engine RPM Sensor
Signal loss or incorrect reading from the diesel engine RPM sensor.
Check Evap Temp Sensor
Failure detected in the evaporator coil temperature sensor.
Check Remote Temp Sensor 1
Signal error in remote temperature sensor number 1.
Check Remote Temp Sensor 2
Signal error in remote temperature sensor number 2.
C2 Check Supply Air Sensor
Supply air sensor error for compartment 2 (C2).
C3 Check Return Air Sensor
Return air sensor error for compartment 3 (C3).
C2 Check Defrost Sensor
Defrost sensor error for compartment 2 (C2).
Check Clutch Circuit
Compressor clutch circuit failure detected during Pretrip.
Check Speed Sol Circ
Failure in the engine speed solenoid circuit (high/low).
C2 Check Heater 1 Circuit
Failure in compartment 2 (C2) heater 1 circuit.
C2 Check Heater 2 Circuit
Failure in compartment 2 (C2) heater 2 circuit.
Check SV3 Circuit
Failure in solenoid valve 3 (SV3) circuit.
Check Eng Preheat Enable Circuit
Failure in the engine preheat enable circuit.
Check Fuel Solenoid Circuit
Failure detected in the fuel solenoid circuit (Run/Stop).
Check Return Air Sensor
Critical error in the return air sensor during Pretrip.
Check Supply Air Sensor
Critical error in the supply air sensor during Pretrip.
Check Coolant Temp Sensor
Engine coolant temperature sensor failure detected during Pretrip.
Check Bypass Circuit
Failure detected in the bypass valve circuit or operation.
Check Battery Current
Battery current reading is outside expected parameters during testing.
Check Ambient Air Sensor
Ambient air temperature sensor reports erratic values or is disconnected.
Check Suction Temp Sensor
Compressor suction temperature sensor is not responding correctly.
C3 Check Heater 1 Circuit
Failure in heating circuit 1 for compartment 3.
C2 Chk Supply Air Sensor
Failure in the compartment 2 supply air sensor.
C3 Check Heater 2 Circuit
Failure in the compartment 3 heating circuit 2.
Check LIV Circuit
Failure in the liquid injection valve (LIV) circuit.
Check UL1
Circuit failure for cylinder unloader number 1 (UL1).
Check Suction Mod Valve
Failure in the Suction Modulation Valve (SMV).
Check SV4 Valve
Failure in the circuit of solenoid valve SV4 (Hot Gas/Bypass Valve).
Check SV1 Valve
Failure in the solenoid valve SV1 circuit.
Check SV3 Valve
Failure in the solenoid valve SV3 circuit.
C2 Check Evap Fan Motor
Fault detected in the compartment 2 evaporator fan motor.
C3 Check Evap Fan Motor
Fault detected during Pretrip in the compartment 3 evaporator fan motor.
Check Evap Outlet Temp
The evaporator outlet temperature sensor does not respond correctly during tests.
Check Heater 1 Circuit
A fault was detected in the Heater 1 electrical circuit during Pretrip.
Check Heater 2 Circuit
Fault detected in the Heater 2 circuit, preventing effective defrost or heating.
Check Evap Fan Motor
General evaporator fan motor error detected during self-inspection.
Check Condenser Fan Motor
Fault in the condenser fan motor, compromising heat dissipation.
Check SV2 Circuit
Fault detected in the SV2 solenoid valve circuit.
Check Clutch
Failure in the coupling or electromagnetic clutch of the compressor.
Check Defrost Term 2 Sensor
Failure in the evaporator 2 defrost termination sensor.
Check Condenser Fan Circuit
Error in the control or power circuit of the condenser fans.
Check Comp Contact Circuit
Failure detected in the compressor contactor circuit (electric/standby mode).
Check Generator Cont Circ
Failure in the generator contactor circuit.
Check Standby Cont Circuit
Failure detected in the emergency power or standby circuit.
C3 Chk Return Air Sensor
Failure in the return air sensor for compartment 3.
Check Damper CR2 Circuit
Failure detected in the damper relay circuit CR2.
Check Damper CR1 Circuit
Failure in the control circuit for damper CR1.
Check Damper – Not Closing
The defrost damper does not close properly, preventing proper airflow during refrigeration.
Econo Calibrate Error
Error detected in the economizer sensor calibration.
Can Not Save Setting
The microprocessor cannot save changes made to settings or parameters.
Microprocessor Error
Generic internal microprocessor error; self-diagnostic failure.
Rear Panel Shutdown Requested
Unit shutdown requested from the rear or remote control panel.
Display Module Error
Communication failure or internal error in the display module.
Check Clutch Slip
Detection of clutch slip; loss of power transfer.
Check Remote Switch 3
Failure or abnormal status detected in auxiliary remote switch 3.
Fuel Pump Relay
Fault detected in the fuel pump relay circuit.
Diesel / Electric Relay
Problem with the relay that selects between Diesel and Electric (Standby) mode.
Bad F13 Fuse
Open or defective F13 fuse; generally affects auxiliary circuits.
Bad F9 Fuse
Open F9 fuse; this fuse typically protects control circuits.
Bad F5 Fuse
Blown F5 fuse; critical for safe system operation.
Bad F3 Fuse
Open F3 fuse; affects vital control logic components.
Bad F10 Fuse
Blown F10 fuse; interrupts critical control functions.
Check Standby Contactor 1
Failure in the electric mode (Standby) contactor number 1.