Low Refrigerant or Leak
124 related codes
System showing low refrigerant charge, suction pressure too low, or refrigerant leak alarms. Common in R-404A, R-452A, R-134a and R-744 systems.
Low Engine Oil Level Warning
The sensor detects an engine oil level insufficient for prolonged operation.
Low Coolant Level
Engine coolant level is below recommended operating limits.
Low Refrigerant Level
Lack of refrigerant in the system's refrigeration circuit.
Alarm 10 – Supply Air Temperature Sensor (SATS) Out of Range
Carrier Transicold alarm AL10 (Alarm Code 10) means the Advance microprocessor has detected the Supply Air Temperature Sensor (SATS/STS) reading is out of range, open, or shorted. The SATS lives in the discharge airstream after the evaporator on Vector, X4, X2 and Supra reefer units and is the primary control sensor when 'Supply' is selected. When AL10 latches, the controller falls back to the Return Air Sensor and box temperature control becomes unstable — a frequent cause of load-quality claims.
High Discharge Pressure
Refrigerant discharge pressure exceeded the safety limit.
Battery Voltage Too High
The system detects a battery voltage exceeding 15.5V DC.
Alarm 17 – High Compressor Discharge Temperature (CDT)
Carrier Transicold alarm code 17 (AL17) triggers when Compressor Discharge Temperature (CDT) climbs above the safety threshold — typically 310°F (154°C) on Vector, X4, X2 and Supra reefer units. The Advance controller shuts the unit down to protect the compressor from thermal breakdown of oil, valve plate damage, and burned windings. AL17 almost always points at a refrigerant-side or airflow problem, not the compressor itself.
Low Refrigerant Press
Refrigerant pressure too low for safe operation.
Low Fuel Shutdown
Unit shut down because fuel level reached zero.
Low Suction Superheat
Low suction superheat, risk of liquid floodback to compressor.
Compression Ratio Exceeded
Pressure ratio between suction and discharge out of range.
High Suction Pressure
Suction pressure higher than allowed limit for the engine.
Check Refrig System
The system detected poor cooling efficiency.
Alternator (Battery Charger) Not Charging
The alternator is not charging the unit's battery while the engine is running.
Defrost Not Complete
The defrost cycle has exceeded the maximum allowed time without completing correctly.
C2 Box Temp Out of Range
Second compartment (C2) temperature is outside allowable limits.
Compressor Motor Overload
The compressor motor overload relay has tripped due to excessive current.
Check Economizer Circuit
Failure in the economizer circuit.
Check Supply Air Sensor
Fault detected on the supply air temperature sensor (SAS). If the unit shut down, repair immediately; otherwise report and repair at end of trip.
Check Comp Discharge Sensor
An abnormal reading is detected at the compressor discharge temperature sensor.
Check Suction Temp Sensor
Failure in the suction temperature sensor circuit.
Check Disch Temp Sensor
Compressor discharge temperature sensor out of range.
Check Suction Temp Sensor
Compressor suction temperature sensor is not responding correctly.
Can Not Pump Down
The system failed to perform internal vacuum (Pump Down) within the established time.
Check Economizer Circuit
A problem was detected in the operation of the economizer circuit.
Check Economizer
Economizer performance is insufficient or null.
Check Evap Superheat
Evaporator superheat is outside design limits.
Check LIV
Flow or mechanical failure in the Liquid Injection Valve (LIV).
Check Suction Mod Valve
Failure in the Suction Modulation Valve (SMV).
High Suction Pressure
Excessively high suction pressure detected during diagnostic tests.
Low Suction Pressure
Suction pressure below the permitted operating limits.
High Discharge Pressure
Dangerously high discharge pressure; risk of high pressure cutout.
Low Discharge Pressure
Insufficient discharge pressure; the unit cannot compress effectively.
High Side Leak
Presumptive detection of a leak in the high-pressure side of the system.
Check Discharge Check Valve
Reported failure in the efficiency or closure of the discharge check valve.
Low Suction Pressure
Critical low suction pressure detected by the transducer.
Dis Press Calibrate Error
Calibration failure of the discharge pressure sensor; data is out of range.
Suct/Evap Calibrate Error
Calibration error in the suction or evaporator pressure sensors.
Low Discharge Superheat
Low discharge superheat detected; risk of liquid floodback to the compressor.
High Economizer Superheat
High superheat at the economizer; reduced cooling efficiency.
Suction Pressure Sensor
Fault in the suction pressure sensor of the refrigeration system.
C3 Chk Evap Outlet Temp
Error in compartment 3 evaporator outlet temperature detected during Pre-Trip.
C2 Chk Evap1 Superheat
Superheat out of range in evaporator 1 of compartment 2.
C3 Chk Evap2 Superheat
Superheat out of range in evaporator 2 of compartment 3.
Check Input Voltage STP4
Voltage detected outside tolerance at the STP4 module.
Battery Voltage High ENCU
Supply voltage to the engine control unit (ENCU) above 15.5V.
Intake Air Pressure Low ENCU
Intake manifold air pressure is below normal.
EES Low Back Pressure
Reported exhaust pressure is unusually low during normal operation.
EES Check Air Control Valve
The system detected a malfunction in the air control valve actuator or circuit.
EES Frequent Regenerations
The system requires regenerations with an abnormally high frequency.
Check (Control) Discharge Air Sensor (Zone)
Failure of the discharge air sensor, which measures the air leaving the evaporator toward the cargo.
High Evaporator Temperature (Zone)
An excessively high evaporator temperature has been detected.
High Discharge Pressure (or Temperature)
The compressor discharge pressure or temperature has exceeded safety limits.
Engine Failed to Crank
The starter motor does not turn or the engine fails to rotate for ignition.
High Engine Coolant Temperature
The diesel engine has reached a temperature above the safety limit.
Cooling Cycle Check (Zone)
The system detects insufficient cooling capacity during monitoring.
Heating Cycle Check (Zone)
The system detects insufficient heating capacity.
Cooling Cycle Fault (Zone)
Critical system failure preventing cooling; unit shuts down to protect cargo.
Heating Cycle Fault (Zone)
Critical failure preventing the unit from generating heat when required.
Refrigeration Capacity Low (Zone)
The unit or zone is not reaching the expected cooling capacity and has been stopped for safety.
Check Engine Coolant Level
The level sensor detects that the engine coolant is below the safe limit.
Unit Forced to Low Speed
The unit has restricted operation to low speed to protect the engine or system.
Unit Forced to Low Speed Modulation
The unit is forced to low speed due to a limitation in the modulation system.
Check Fuel System
The system has detected problems in fuel supply or suction.
Low Battery Voltage
The battery voltage powering the microprocessor is too low.
Low Engine Oil Level
The sensor indicates the engine oil level is below the safe limit.
High Compressor Temp
The compressor temperature is unusually high, approaching the safety limit.
High Compressor Temp Shutdown
The unit stopped to protect the compressor due to excessive temperature.
Check Discharge Pressure Sensor
The controller detected an erroneous signal from the discharge pressure sensor.
Check Suction Pressure Sensor
The controller detected an erroneous signal from the suction pressure sensor.
ETV Fault – Electronic Throttling Valve Circuit (Code 89)
Thermo King alarm code 89 indicates a failure in the Electronic Throttling Valve (ETV) control circuit. The ETV is a stepper-motor modulating valve in the suction line that regulates suction pressure and compressor loading on Thermo King SB-, SLXi, SLXe, SLX, SLX Whisper, T-Series, Precedent and TriPac reefer units. When the microprocessor cannot drive or read the ETV stepper coils correctly, it logs Code 89 and forces the unit into a protective mode — often unable to hold setpoint or pull down.
Low Compressor Suction Pressure
Dangerously low compressor suction pressure detected.
Low Fuel Level
Tank fuel level is below the preset safety limit.
High Compressor Pressure Ratio
Excessive pressure ratio detected between compressor suction and discharge, risking mechanical integrity.
Controlling on Evap Coil Outlet Temp (CR)
Unit is controlling temperature based on evaporator outlet due to a primary sensor failure.
Low Evaporator Coil Temperature (CR)
Evaporator coil temperature is dangerously low, which may lead to icing or freezing.
Check High Discharge Pressure Sensor
Error in the high discharge pressure sensor (Replaced by code 86 in newer models).
Check Suction Line Sol Circuit (Zone)
Failure in the suction line solenoid valve circuit for a specific zone.
Check High Pressure Cut Out Switch
Fault in the High Pressure Cut Out (HPCO) switch or its circuit.
Check PMW Liquid Injection Circuit
Failure in the Pulse Width Modulation (PMW) liquid injection circuit, crucial for compressor cooling.
Check Back Pressure Regulator (CR)
Indicates a problem with the suction pressure regulator or back pressure regulator, affecting temperature stability.
Low Suction Pressure Switch Failure
Inconsistent state or failure detected in the low suction pressure switch.
Check Suction/Liquid Heat Exchanger Bypass Valve
Indicates a problem with the operation of the suction/liquid heat exchanger bypass valve.
Check Evaporator Pressure Sensor (CR)
The evaporator pressure sensor is sending signals that are out of range.
Low CO2 Fuel Level (CR)
Low level of CO2 fuel detected in the storage tank.
Check Display Discharge Air Sensor (Zone)
The display discharge air temperature sensor is presenting erroneous readings.
High Compressor Suction Pressure (Scroll Only)
Excessively high suction pressure detected in Scroll-type compressors.
Low Compressor Suction Ratio (Scroll Only)
Suction pressure ratio below safe operating limits for the Scroll compressor.
Low Compressor Discharge Pressure (Scroll Only)
Scroll compressor discharge pressure too low during operation.
Minimum ETV Discharge Superheat Temp (Scroll)
ETV controlled discharge superheat is at the minimum thermal limit.
Generator Ground Fault
Current leakage to ground detected in the generator circuit.
Check Battery Charger Input Power
Problem detected with AC input power to the battery charger.
Check Battery Charger Output Power
Battery charger is not delivering expected output power for charging.
Battery Charger External/Environmental Fault
Battery charger failure caused by external or environmental factors.
Battery Charger Indicated Conditions
The battery charger has detected abnormal internal conditions requiring attention.
Generator Operational Limit Output Current
The generator has reached or exceeded its operating output current limit.
Failed J1939 CAN Comm Base Controller/Charger
J1939 CAN communication failure between the base controller and the battery charger.
Low Pressure Differential (Scroll only)
Low differential pressure detected across the compressor (Scroll only).
Battery Charger Fault – Unit Forced to Low Speed
The battery charger has a fault, and the unit is forced to low speed to protect the system.
Battery Charger Internal Short
An internal short circuit has been detected within the battery charger component.
Battery Charger External Short
A short circuit has been detected in the wiring or load external to the battery charger.
Battery Charger Output Voltage Exceeded Limit
The battery charger output voltage exceeded the maximum safety limit.
Battery Charger Operating Bulk Voltage Out of Range
The charging voltage during the 'Bulk' stage is outside the normal operating range.
Battery Charger Temperature Below Operating Range
The battery charger temperature is below the minimum operating range.
Battery Charger AC Input Overvoltage
AC input voltage to the battery charger exceeds the safe limit.
Battery Charger Internal Overvoltage Fault
Overvoltage fault detected within the battery charger internal circuits.
Battery Charger Internal Temp Sensor Fault
Fault in the sensor monitoring the internal temperature of the battery charger.
Battery Charger Charging – Low Battery
The charger detects an extremely low battery voltage during the charging cycle.
Check Exhaust Pressure Sensor
Fault in the exhaust pressure sensor, affecting emission control.
Check Intake Pressure Sensor
Fault in the Manifold Absolute Pressure (MAP) sensor.
Rail Pressure Fault
Fuel rail pressure is outside safe operating parameters.
High Temperature Alarm
Temperature above the configured limit.
High Discharge Pressure
High pressure switch opened due to overpressure.
Low Suction Pressure
Low pressure switch activated.
Compressor Thermal Protector Open
Protection module detected compressor overheating.
High Discharge Pressure (HP)
High pressure switch activated on Bitzer compressor.
Low Suction Pressure (LP)
Low pressure switch activated.
High Discharge Gas Temperature
PTC sensor in compressor head exceeded 140°C.
Oil Differential Pressure Failure
Delta P-MP10 detected low oil pressure for >90 seconds.
Battery Charger Operating Derated Due to High Temp
Battery charger has reduced its output current because internal temperature is too high.