All symptoms

Evaporator / Condenser Fan Problems

133 related codes

Fan motor not running, locked rotor, overcurrent on evaporator or condenser fans, or airflow alarms.

00004
Carrier Transicold

Low Refrigerant Level

Lack of refrigerant in the system's refrigeration circuit.

AL10
Carrier Transicold

Alarm 10 – Supply Air Temperature Sensor (SATS) Out of Range

Carrier Transicold alarm AL10 (Alarm Code 10) means the Advance microprocessor has detected the Supply Air Temperature Sensor (SATS/STS) reading is out of range, open, or shorted. The SATS lives in the discharge airstream after the evaporator on Vector, X4, X2 and Supra reefer units and is the primary control sensor when 'Supply' is selected. When AL10 latches, the controller falls back to the Return Air Sensor and box temperature control becomes unstable — a frequent cause of load-quality claims.

00012
Carrier Transicold

High Coolant Temp

Engine temperature has exceeded the maximum safe operating limit.

00013
Carrier Transicold

High Discharge Pressure

Refrigerant discharge pressure exceeded the safety limit.

00014
Carrier Transicold

High A/C Amps

High electrical current detected in AC system components.

00017
Carrier Transicold

Alarm 17 – High Compressor Discharge Temperature (CDT)

Carrier Transicold alarm code 17 (AL17) triggers when Compressor Discharge Temperature (CDT) climbs above the safety threshold — typically 310°F (154°C) on Vector, X4, X2 and Supra reefer units. The Advance controller shuts the unit down to protect the compressor from thermal breakdown of oil, valve plate damage, and burned windings. AL17 almost always points at a refrigerant-side or airflow problem, not the compressor itself.

00018
Carrier Transicold

Low Refrigerant Press

Refrigerant pressure too low for safe operation.

00022
Carrier Transicold

Low Suction Superheat

Low suction superheat, risk of liquid floodback to compressor.

00023
Carrier Transicold

A/C Current Over Limit

AC current consumption exceeded pre-set limits.

00032
Carrier Transicold

Failed To Start – Manual

Failure to start the unit in manual mode.

00035
Carrier Transicold

Check Starter Circuit

Anomaly detected in the starter motor electrical circuit.

00036
Carrier Transicold

Check Coolant Temp

Engine temperature is not rising or is out of expected range.

00053
Carrier Transicold

Box Temp Out of Range

The temperature inside the box is outside the established tolerance range relative to the setpoint.

00054
Carrier Transicold

Defrost Not Complete

The defrost cycle has exceeded the maximum allowed time without completing correctly.

00056
Carrier Transicold

Check Evaporator Air Flow

The system has detected a significant restriction in airflow through the evaporator.

00062
Carrier Transicold

C2 Box Temp Out of Range

Second compartment (C2) temperature is outside allowable limits.

00071
Carrier Transicold

Bad F2 or F3 Fuse

Failure in fuses F2 or F3 which control vital accessory power circuits.

00074
Carrier Transicold

AC Phase Reversed

External AC power phase is reversed, which can damage motors.

00075
Carrier Transicold

Compressor Motor Overload

The compressor motor overload relay has tripped due to excessive current.

00076
Carrier Transicold

Condenser Motor Overheated

The condenser fan motor thermal sensor reports excessive temperature.

00077
Carrier Transicold

Evap Motor Overheated

The evaporator fan motor is operating above its safe temperature threshold.

00095
Carrier Transicold

Check CDCON Relay Coil

Failure in the CDCON relay coil (Condenser Fan).

00098
Carrier Transicold

Check High Temperature Thermostat

Activation of the high temperature thermostat (Overheat protection).

00100
Carrier Transicold

Overload/Ground Fault

Electrical overload or ground fault detected in the system.

00101
Carrier Transicold

C2 Evap Motor Overheated

Overheating detected in the Compartment 2 evaporator motor.

00102
Carrier Transicold

C3 Evap Motor Overheated

Overheating detected in the Compartment 3 evaporator motor.

00108
Carrier Transicold

Check 3LSV Circuit

Issue in the Liquid Line Solenoid Valve 3 (3LSV) circuit.

00109
Carrier Transicold

Check 1EVCON Relay Coil

Fault in the evaporator motor contactor 1 (1EVCON).

00110
Carrier Transicold

Check 2EVCON Relay Coil

Fault in the evaporator motor contactor 2 (2EVCON).

00111
Carrier Transicold

Check 3EVCON Relay Coil

Fault in the evaporator motor contactor 3 (3EVCON).

00128
Carrier Transicold

Low/Unbalanced A/C Amps

Low or unbalanced AC current amperage detected at the generator.

00131
Carrier Transicold

Check Evap Temp Sensor

Failure detected in the evaporator coil temperature sensor.

00136
Carrier Transicold

C2 Check Supply Air Sensor

Supply air sensor error for compartment 2 (C2).

00138
Carrier Transicold

C3 Check Return Air Sensor

Return air sensor error for compartment 3 (C3).

00140
Carrier Transicold

C3 Check Defrost Sensor

Defrost sensor error for compartment 3 (C3).

P00149
Carrier Transicold

Check SV3 Circuit

Failure in solenoid valve 3 (SV3) circuit.

P00177
Carrier Transicold

Check Evap Superheat

Evaporator superheat is outside design limits.

P00180
Carrier Transicold

Check Suction Mod Valve

Failure in the Suction Modulation Valve (SMV).

P00184
Carrier Transicold

C2 Check Evap Fan Motor

Fault detected in the compartment 2 evaporator fan motor.

P00185
Carrier Transicold

C3 Check Evap Fan Motor

Fault detected during Pretrip in the compartment 3 evaporator fan motor.

P00186
Carrier Transicold

Check Evap Outlet Temp

The evaporator outlet temperature sensor does not respond correctly during tests.

P00189
Carrier Transicold

Check Evap Fan Motor

General evaporator fan motor error detected during self-inspection.

P00190
Carrier Transicold

Check Condenser Fan Motor

Fault in the condenser fan motor, compromising heat dissipation.

P00196
Carrier Transicold

High Discharge Pressure

Dangerously high discharge pressure; risk of high pressure cutout.

P00205
Carrier Transicold

Check Defrost Term 2 Sensor

Failure in the evaporator 2 defrost termination sensor.

P00206
Carrier Transicold

Check Condenser Fan Circuit

Error in the control or power circuit of the condenser fans.

P00212
Carrier Transicold

C3 Check Defrost Sensor

Failure in the compartment 3 defrost sensor.

P00215
Carrier Transicold

Check Damper – Not Open

The defrost damper is stuck in the closed position or is not opening properly.

P00216
Carrier Transicold

Check Damper – Not Closing

The defrost damper does not close properly, preventing proper airflow during refrigeration.

00224
Carrier Transicold

Standby Maintenance Due

The scheduled interval for electric motor (Standby) service has expired.

00243
Carrier Transicold

Suct/Evap Calibrate Error

Calibration error in the suction or evaporator pressure sensors.

03000
Carrier Transicold

Motor Overload 1

Overload detected in the electric motor or fan motor 1.

05019
Carrier Transicold

Check CDCON Relay Coil Two

Failure in coil 2 of the condenser contactor relay (CDCON).

06000
Carrier Transicold

Cond. Motor 2 Overheated

Internal overheat protection for condenser motor 2 activated.

07003
Carrier Transicold

C2 Chk Evap Temp Sensor

Indicates a problem with the evaporator temperature sensor in compartment 2.

P12001
Carrier Transicold

C2 Chk Evap Outlet Temp

Error in compartment 2 evaporator outlet temperature detected during Pre-Trip.

P12002
Carrier Transicold

C3 Chk Evap Outlet Temp

Error in compartment 3 evaporator outlet temperature detected during Pre-Trip.

P13000
Carrier Transicold

Check Condenser Fan 2 Circuit

Failure in the condenser fan number 2 circuit during self-check.

P14000
Carrier Transicold

C2 Chk Evap1 Superheat

Superheat out of range in evaporator 1 of compartment 2.

P14001
Carrier Transicold

C2 Chk Evap2 Superheat

Superheat out of range in evaporator 2 of compartment 2.

P14002
Carrier Transicold

C3 Chk Evap1 Superheat

Superheat out of range in evaporator 1 of compartment 3.

P14003
Carrier Transicold

C3 Chk Evap2 Superheat

Superheat out of range in evaporator 2 of compartment 3.

25100
Carrier Transicold

No Comm From Micro to STP1

Communication failure between the microprocessor and the stepper motor module 1 (STP1).

25101
Carrier Transicold

Over Current STP1

Overcurrent detected in the stepper motor 1 (STP1) circuit.

25200
Carrier Transicold

No Comm From Micro to STP2

Communication failure between the microprocessor and the stepper motor module 2 (STP2).

25201
Carrier Transicold

Over Current STP2

Overcurrent detected in the stepper motor 2 (STP2) circuit.

25300
Carrier Transicold

No Comm From Micro to STP3

Communication failure between the microprocessor and stepper motor module 3 (STP3).

25301
Carrier Transicold

Over Current STP3

Overcurrent detected in the stepper motor 3 (STP3) circuit.

25400
Carrier Transicold

No Comm From Micro to STP4

Communication failure between the microprocessor and stepper motor module 4 (STP4).

25401
Carrier Transicold

Over Current STP4

Overcurrent detected in the stepper motor 4 (STP4) circuit.

26101
Carrier Transicold

Engine Over Heat ENCU

Engine has exceeded the maximum safety temperature limit configured by the ENCU.

26102
Carrier Transicold

Water Temp Low ENCU

Coolant temperature too low; engine failing to reach operating temperature.

02
Thermo King

Check Evaporator Coil Sensor (Zone)

The microprocessor has detected a failure or out-of-range reading in the evaporator coil sensor.

04
Thermo King

Check (Control) Discharge Air Sensor (Zone)

Failure of the discharge air sensor, which measures the air leaving the evaporator toward the cargo.

09
Thermo King

High Evaporator Temperature (Zone)

An excessively high evaporator temperature has been detected.

10
Thermo King

High Discharge Pressure (or Temperature)

The compressor discharge pressure or temperature has exceeded safety limits.

13
Thermo King

Sensor Check (Zone)

The microprocessor has detected an unusual discrepancy between temperature sensors.

17
Thermo King

Engine Failed to Crank

The starter motor does not turn or the engine fails to rotate for ignition.

26
Thermo King

Check Refrigeration Capacity (Zone)

Refrigeration capacity is lower than expected for the current setpoint.

27
Thermo King

Vapor Motor RPM High (CR)

Steam motor or electric compressor revolutions exceed the safety limit.

30
Thermo King

Defrost Damper Stuck Closed (Zone)

The evaporator damper has become stuck in the closed position.

32
Thermo King

Refrigeration Capacity Low (Zone)

The unit or zone is not reaching the expected cooling capacity and has been stopped for safety.

36
Thermo King

Electric Motor Failed to Run

The backup electric motor does not start when standby mode operation is required.

41
Thermo King

Check Engine Coolant Temp

Engine coolant temperature is unusually high or the sensor is failing.

46
Thermo King

Check Air Flow (Zone)

Restriction detected in evaporator airflow in the indicated zone.

56
Thermo King

Check Evaporator Fan Low Speed (Zone)

Failure detected in the evaporator fans' low-speed circuit.

57
Thermo King

Check Evaporator Fan High Speed (Zone)

A fault was detected in the high-speed circuit of the evaporator fans.

63
Thermo King

Engine or Vapor Motor Stopped

The diesel engine or electric motor stopped unexpectedly due to mechanical or fuel reasons.

65
Thermo King

Abnormal Temperature Differential (Zone)

Abnormal temperature differential detected in a specific zone (evaporator).

89
Thermo King

ETV Fault – Electronic Throttling Valve Circuit (Code 89)

Thermo King alarm code 89 indicates a failure in the Electronic Throttling Valve (ETV) control circuit. The ETV is a stepper-motor modulating valve in the suction line that regulates suction pressure and compressor loading on Thermo King SB-, SLXi, SLXe, SLX, SLX Whisper, T-Series, Precedent and TriPac reefer units. When the microprocessor cannot drive or read the ETV stepper coils correctly, it logs Code 89 and forces the unit into a protective mode — often unable to hold setpoint or pull down.

93
Thermo King

Low Compressor Suction Pressure

Dangerously low compressor suction pressure detected.

97
Thermo King

Failed Remote Return Air Sensor (CR)

Remote return air sensor failure preventing accurate zone temperature reading.

99
Thermo King

High Compressor Pressure Ratio

Excessive pressure ratio detected between compressor suction and discharge, risking mechanical integrity.

100
Thermo King

Heater Fan Failure (CR)

Fault detected in the heater fan motor or circuit.

101
Thermo King

Controlling on Evap Coil Outlet Temp (CR)

Unit is controlling temperature based on evaporator outlet due to a primary sensor failure.

102
Thermo King

Low Evaporator Coil Temperature (CR)

Evaporator coil temperature is dangerously low, which may lead to icing or freezing.

104
Thermo King

Check Remote Fan Speed (Zone)

The controller cannot detect or maintain the required speed for the remote zone fans.

107
Thermo King

Check Condenser Inlet Sol Circuit

Error detected in the condenser inlet solenoid valve circuit.

110
Thermo King

Check Suction Line Sol Circuit (Zone)

Failure in the suction line solenoid valve circuit for a specific zone.

112
Thermo King

Check Remote Fans (Zone)

The remote zone fans are not operating as required.

115
Thermo King

Check High Pressure Cut Out Switch

Fault in the High Pressure Cut Out (HPCO) switch or its circuit.

117
Thermo King

Auto Switch from Diesel to Electric

The unit has automatically switched from diesel operation to electric motor operation.

118
Thermo King

Auto Switch from Electric to Diesel

The unit has automatically switched from electric motor to diesel operation.

122
Thermo King

Check Diesel/Electric Circuit

Error when attempting to switch between diesel and electric mode or vice versa.

123
Thermo King

Check Evap Coil Inlet Temp Sensor (CR)

Failure in the evaporator coil inlet temperature sensor (CR).

124
Thermo King

Check Evap Coil Outlet Temp Sensor (CR)

Failure in the evaporator coil outlet temperature sensor (CR).

137
Thermo King

Check Damper Motor Heater Output

Fault in the heater circuit for the defrost damper motor.

143
Thermo King

Check Remote Drain Hose Heater Output (Zone)

Error in the remote drain hose heater output in a specific zone.

147
Thermo King

Check Multi-Temp Fan Speed Control Output (Zone)

Error in the speed control of the multi-temperature evaporator fans.

150
Thermo King

Sensor Out of Range Low (DAS and HMI) (Zone)

A sensor (air, evaporator) is reporting a measurement below the minimum limit.

175
Thermo King

Check Electronic Expansion Valve (CR)

Failure in the electronic expansion valve (EEV) circuit or mechanism.

176
Thermo King

Check Evaporator Pressure Sensor (CR)

The evaporator pressure sensor is sending signals that are out of range.

500
Thermo King

Check Host Evaporator Blower Low Speed

Problem detected in the low speed of the main evaporator blower.

501
Thermo King

Check Host Evaporator Blower High Speed

Problem detected in the high-speed operation of the host evaporator blower.

505
Thermo King

Check Roadside Condenser Fan Motor Speed Circuit

Fault in the speed control circuit of the roadside condenser fan motor.

506
Thermo King

Check Curbside Condenser Fan Motor Speed Circuit

Fault in the speed control circuit of the curbside condenser fan motor.

512
Thermo King

High Compressor Suction Pressure (Scroll Only)

Excessively high suction pressure detected in Scroll-type compressors.

518
Thermo King

Generator Ground Fault

Current leakage to ground detected in the generator circuit.

521
Thermo King

Battery Charger External/Environmental Fault

Battery charger failure caused by external or environmental factors.

526
Thermo King

Generator Operational Limit Output Current

The generator has reached or exceeded its operating output current limit.